Edison had installed his historic first great central-station system in New York on the multiple arc system covered by his feeder and main invention, which resulted in a notable saving in the cost of conductors as against a straight two-wire system throughout of the "tree" kind.

Edison's results, became one of his most ardent advocates, and did much to facilitate the introduction of the light. This station supplied its customers by a network of feeders and mains of the standard underground two-wire Edison tubing-conductors in sections of iron pipe such as was used subsequently in New York, Milan, and other cities.

With these models were shown two cubes which represented one one-hundredth of the actual quantity of copper required for each quarter of the district by the two-wire tree system as compared with the feeder system under like conditions. The total weight of copper for the four quarter districts by the tree system was 803,250 pounds, but when the feeder system was used it was only 128,739 pounds!

Screw the end of a piece of heavy copper wire to the lower post of the arrester and run it to the ground, on porcelain knobs if necessary, and solder it to an iron rod or pipe which you have driven into the earth. Run a wire from the top post through the leading-in insulator and connect it with the slider of your tuning coil. A Two-wire Aerial.

They fashioned a two-wire antenna with the spreaders left on the island by Hal's cousin; connected a lead-in to this, and then Cub and Bud climbed the two trees and, with the aid of ropes tied around their waists and the guiding assistance of their companions below, drew the "ether-wave feeler" up to a lofty elevation and fastened it as nearly taut as they could stretch and hold it.

The commercial value of this invention may be appreciated from the fact that by the application of its principles there is effected a saving of 62 1/2 per cent. of the amount of copper over that which would be required for conductors in any previously devised two-wire system carrying the same load.

Edison is as much a necessity in their operation as it is in the electric lighting systems, whether those systems be operated on the old two-wire plan, the three-wire plan or by means of alternating currents. Passing from a review of central station plants and distribution system naturally bring us to the operating cost and the factors governing profit and loss of the enterprise.

Screw the end of a piece of heavy copper wire to the lower post of the arrester and run it to the ground, on porcelain knobs if necessary, and solder it to an iron rod or pipe which you have driven into the earth. Run a wire from the top post through the leading-in insulator and connect it with the slider of your tuning coil. A Two-wire Aerial.

Taking two single lines, he instructed the operator at the other end to join them, forming a two-wire circuit. The results justified him. At last a line had been attained which could be depended upon to carry the conversation. No sooner was one problem solved than another presented itself. What to do with the constantly increasing number of wires was a pressing difficulty.

We had two-wire underground feeders, sent without any plans or specifications for their installation. The station had neither voltmeter nor ammeter. The current pressure was regulated by a galvanometer. We were using coal costing $12 a ton, and were paid for our light in currency worth fifty cents on the dollar.